{"entity":{"name":"Acme Supplies SRL","registration":"BE0123456789","site":"Brussels warehouse"},"equipment":{"id":"FL-LINDE-2021-03","description":"Counterbalance forklift, 3-ton capacity, LPG","location":"Brussels warehouse — loading bay 2","manufacturer":"Linde Material Handling","model":"H30T-01","serial":"H2X392K00315"},"period":{"start_date":"2026-01-01","end_date":"2026-03-31"},"entries":[{"date":"2026-01-12","maintenance_type":"preventive","description":"500-hour service per OEM schedule: oil + filter, hydraulic filter, air filter, mast chain inspection and lubrication, tyre inspection. Operating hours at service: 2.980.","parts_replaced":["Engine oil 15W-40 (7 L)","Oil filter Linde 0009842704","Hydraulic filter 0009831407","Air filter 0009839001"],"downtime_hours":3.5,"performed_by":"Jean-Michel Petit (Acme in-house technician)","next_due_date":"2026-04-12"},{"date":"2026-02-05","maintenance_type":"inspection","description":"Statutory annual LOLER-equivalent lifting-equipment inspection by accredited third party (Bureau Veritas). Load test at 100% rated capacity, brake test, mast and chain inspection, safety decals. Result: pass, certificate BV-BE-2026-1170 issued.","downtime_hours":2.0,"performed_by":"Bureau Veritas Belgium","next_due_date":"2027-02-05"},{"date":"2026-02-22","maintenance_type":"corrective","description":"Hydraulic leak reported by operator at mast lift cylinder rod seal. Replaced rod seal and wiper, topped up hydraulic oil (2 L), cleaned mast. Forklift returned to service same day.","parts_replaced":["Linde mast lift cylinder seal kit 0009293012","Shell Tellus S2 M46 hydraulic oil (2 L)"],"downtime_hours":4.5,"performed_by":"Jean-Michel Petit (Acme in-house technician)"},{"date":"2026-03-20","maintenance_type":"predictive","description":"Quarterly thermal imaging of battery tray, drive motor, hydraulic pump and mast bearings. No hotspots detected; report filed in CMMS (ref. TI-2026-Q1-FL03).","downtime_hours":0.5,"performed_by":"Jean-Michel Petit (Acme in-house technician)","next_due_date":"2026-06-20"}],"upcoming_due":[{"equipment_reference":"FL-LINDE-2021-03 — 500h service","due_date":"2026-04-12","maintenance_type":"preventive","assigned_to":"Jean-Michel Petit"},{"equipment_reference":"FL-LINDE-2021-03 — quarterly thermal imaging","due_date":"2026-06-20","maintenance_type":"predictive","assigned_to":"Jean-Michel Petit"}],"log_owner":{"name":"Marc Dewinter","role":"Warehouse Operations Manager"}}